    "id": "643ba0ef-c401-42c0-80c4-3926dcb9c9d0",
    "title": "Pre-Listing Inspection Report",
    "property_address": "478 S. Jackson St. | Pinedale WY | 82941",
    "client_name": "Micki Sluyter",
    "inspection_date": "2026-05-14",
    "status": "published",
    "share_token": "cf46eef285e5200b5f484baa",
    "created_at": "2026-05-14T22:39:10.448537+00:00",
    "summary_text": "Overall, the home is in good condition. The electrical was installed by a qualified individual and is installed according to the 2023 NEC requirements. The foundation appears to be performing well, and there are no signs of significant settlement. The roof has some minor flashing details that should be addressed. The shingles are noticeably damaged, likely from the installers walking on the surface. The steep pitch of the roof likely required the use of spiked shoes. The damage on these shingles is apparent. It doesn't appear that the surface is damaged to the point of leaking, and repairs may be cost inefficient as the damage is primarily cosmetic. The total roof life has likely been reduced by the damage and potential buyers may note this. A few of the windows still have protective tape over the weep holes. These should be removed. A few of the trim pieces around the windows are missing paint on their end grain. There is a spot on the siding that should be touched up with paint on the North side of the garage. \n\nThe on-demand water heater and in-floor heating system is installed on a piece of OSB between the home and the garage. Technically, this does not meet fire separation requirements for attached garages. There is not much that can be done at this point to add a proper fire separation. Fire rated caulk or foam should be added around the main water shut-off penetration in the garage roof. Due to the living space above, any penetration in the garage ceiling needs to be properly sealed to maintain the fire wall separation.   \n",
    "home_photo_url": null,
    "inspector_name": null,
    "gis_map_url": null
  },
  {
    "id": "9d08d452-aae8-4a59-bb5f-8d86552fe485",
    "title": "Test Report",
    "property_address": "",
    "client_name": "",
    "inspection_date": "2026-05-19",
    "status": "draft",
    "share_token": "9d46c2ae5023e6abc13e6551",
    "created_at": "2026-05-16T05:01:04.028325+00:00",
    "summary_text": "",
    "home_photo_url": "https://lxlnbgjlxnwpfioiqaek.supabase.co/storage/v1/object/public/inspection-photos/9d08d452-aae8-4a59-bb5f-8d86552fe485/home/886f62b8-5cf0-4af8-8d64-282ff56942ec.jpg",
    "inspector_name": "Douglas Macdonald",
    "gis_map_url": "https://lxlnbgjlxnwpfioiqaek.supabase.co/storage/v1/object/public/inspection-photos/9d08d452-aae8-4a59-bb5f-8d86552fe485/gis-map/6f6e79fc-e983-455c-ba84-f4d6607ef577.png"
  },
  {
    "id": "b75efa6f-7c8b-4cd3-86d6-92e0fe496e5e",
    "title": "Home Inspection Report",
    "property_address": "825 Sundance Drive",
    "client_name": "Alexandra Erramouspe",
    "inspection_date": "2026-05-15",
    "status": "published",
    "share_token": "af9e434b9ed1f29c7979ee3f",
    "created_at": "2026-05-16T03:28:40.371898+00:00",
    "summary_text": "The Summary provides a quick snapshot of the inspection. The report should still be read in its entirety. This home inspection report should be used as a home guide if you decide to purchase the home. It contains a lot of information on the systems in the home; including model numbers, locations of gas and water shut-offs, and various other home systems. The filter option can be used to filter between the finding types \"Safety Defect\", \"Major Defect\", and \"Minor Defect\". \n\nOverall, the home is in good condition. The shingles are in good condition, with little granule loss noted. The foundation and siding both appear to be performing well. The appliances were all observed to be operational. The roof structure does have some soft spots. This appears to be a result of holes previously cut for vents, and thinner plywood. The heavier shingles used should have at least 3/4\" roof decking underneath to provide rigidity. The attic space is also not well ventilated. Ridge vents have been installed, but no soffit vents have been installed. The breaker size in the subpanel is improperly sized. The service size for the home is 100-amps, which is smaller than the modern 200-amp services that are now standard. The door between the garage and the home has a pet door installed. This no longer meets fire code for fire separation. This can sometimes be a problem for lending transactions if the appraiser identifies it. ",
    "home_photo_url": "https://lxlnbgjlxnwpfioiqaek.supabase.co/storage/v1/object/public/inspection-photos/b75efa6f-7c8b-4cd3-86d6-92e0fe496e5e/home/efc95642-c494-4ab2-ad04-ea3040a47d2d.jpg",
    "inspector_name": "Douglas Macdonald",
    "gis_map_url": "https://lxlnbgjlxnwpfioiqaek.supabase.co/storage/v1/object/public/inspection-photos/b75efa6f-7c8b-4cd3-86d6-92e0fe496e5e/gis-map/b8bd50e4-87b1-4e06-9227-1b03cad69fc3.png"
  },
  {
    "id": "d703bc55-1826-4f9b-843e-ab95868124ec",
    "title": "Home Inspection Report",
    "property_address": "80 First North Road | Big Piney | WY | 83113",
    "client_name": "Sam Wheeler",
    "inspection_date": "2026-05-22",
    "status": "draft",
    "share_token": "fc002e1f37a81ee78b115001",
    "created_at": "2026-05-21T22:32:07.954554+00:00",
    "summary_text": "",
    "home_photo_url": null,
    "inspector_name": "Douglas Macdonald",
    "gis_map_url": "https://lxlnbgjlxnwpfioiqaek.supabase.co/storage/v1/object/public/inspection-photos/d703bc55-1826-4f9b-843e-ab95868124ec/gis-map/883fa035-c495-4879-9fb6-af6df1b43914.png"
  },
  {
    "id": "1ee566d6-e5ab-4e6c-93ab-4d7e813f4d13",
    "title": "9508 US HWY 191 Home Inspection Report",
    "property_address": "9508 US HWY 191 | Pinedale | WY | 82941",
    "client_name": "Michelle Hymas",
    "inspection_date": "2026-06-16",
    "status": "published",
    "share_token": "57e876ab19b483fee0aac530",
    "created_at": "2026-06-16T23:16:10.665107+00:00",
    "summary_text": "Overall, the home is in good condition. The home has EIFS siding installed, which has a history of moisture problems especially with older installations like this one. This siding may trap water behind the foam insulation and lead to damage in the exterior sheathing and framing. The siding must be completely sealed and any cracks or damage must be addressed immediately to prevent water penetration. There are a few damaged areas on the siding and cracks around windows. There is a bulging spot near the window well on the East side. There does not appear to be signs of moisture intrusion on the interior of the home. However, the installation has the siding in contact with grade, which can lead to moisture penetration and water damage. \n\nThere are several electrical issues with the home as well. The neutrals and grounds have been illegally bonded in multiple locations. There is missing GFCI protection in several locations. The home does not have proper smoke or carbon monoxide detectors installed. Some of these electrical issues may delay or prevent lending on the home. ",
    "home_photo_url": "https://lxlnbgjlxnwpfioiqaek.supabase.co/storage/v1/object/public/inspection-photos/1ee566d6-e5ab-4e6c-93ab-4d7e813f4d13/home/1b72da8f-63f6-4114-979a-92848f67f202.JPG",
    "inspector_name": "Douglas Macdonald",
    "gis_map_url": "https://lxlnbgjlxnwpfioiqaek.supabase.co/storage/v1/object/public/inspection-photos/1ee566d6-e5ab-4e6c-93ab-4d7e813f4d13/gis-map/755254d8-2c61-4327-81f1-8d66e1245842.png"
  },
  {
    "id": "fac32eec-5950-497f-866d-3cf3cc2c9095",
    "title": "1020 Sherry Dr. Home Inspection Report",
    "property_address": "1020 Sherry Dr. | Riverton | WY | 82501",
    "client_name": "Makenzie Valerio",
    "inspection_date": "2026-08-06",
    "status": "published",
    "share_token": "1b7ddbf2f9ec5db4ee5ab5fe",
    "created_at": "2026-08-07T02:00:15.69383+00:00",
    "summary_text": "Overall, the home is in good condition. The roof and foundation are both in good condition. The electrical in the home is old and outdated. The small 50-amp service may not be adequate for a modern home with many electrical appliances. A full service upgrade can be expensive. There are issues with the bonding of the neutrals and the grounds in the garage panel. The TPR valve for the water heater was observed to be dripping during the inspection. It should be verified that this valve has stopped leaking or the valve should be replaced. The entire report must be read for a full list of observed defects. ",
    "home_photo_url": "https://lxlnbgjlxnwpfioiqaek.supabase.co/storage/v1/object/public/inspection-photos/fac32eec-5950-497f-866d-3cf3cc2c9095/home/868b0af1-d39f-4fde-a936-1ac2fda90681.jpg",
    "inspector_name": "Douglas Macdonald",
    "gis_map_url": "https://lxlnbgjlxnwpfioiqaek.supabase.co/storage/v1/object/public/inspection-photos/fac32eec-5950-497f-866d-3cf3cc2c9095/gis-map/7718d363-c1d0-4bf3-92fa-3cfc67a54e63.png"
  },
  {
    "id": "2774d73f-0426-464b-9c04-00b08c0495c1",
    "title": "Home Inspection Report",
    "property_address": "80 First North Rd.",
    "client_name": "Sam Wheeler",
    "inspection_date": "2026-05-22",
    "status": "published",
    "share_token": "91cec935323cdaec627c061a",
    "created_at": "2026-05-24T16:51:04.354632+00:00",
    "summary_text": "Overall, the home is in poor condition. It has not been properly maintained through the years, and there is a significant amount of deferred maintenance. The foundation has settled significantly on the North side. The floor noticeably slopes towards the North. The concrete masonry unit addition is cracked and leaning near the NE corner of the home. The back porch has been water damaged likely beyond repair. The detached garage shows signs of water damage in the roof structure, especially around the wood stove chimney. The water quality is questionable for the home as well. It appears from County records that the water was tested in 1982 and was found to contain elevated levels of minerals, sodium, and sulfates. The water may need to be re-tested to ensure it is safe for human consumption. The electrical and many of the appliances are outdated and may be near the end of their usable life. The siding has not been maintained either and shows signs of wear and water staining. The home likely requires a high level of repair and updating. Financing may be difficult to secure for the home due to the level of depreciation observed.",
    "home_photo_url": "https://lxlnbgjlxnwpfioiqaek.supabase.co/storage/v1/object/public/inspection-photos/2774d73f-0426-464b-9c04-00b08c0495c1/home/bb0d61ce-6992-4b83-ae85-6e04450f7d4a.JPG",
    "inspector_name": "Douglas Macdonald",
    "gis_map_url": "https://lxlnbgjlxnwpfioiqaek.supabase.co/storage/v1/object/public/inspection-photos/2774d73f-0426-464b-9c04-00b08c0495c1/gis-map/a8892b61-84d9-4cc8-a6a7-3fd0a00cf727.png"
  },
  {
    "id": "d499cc39-424f-44ac-90b7-3c3f919ceb48",
    "title": "216 E. Birch Street Home Inspection Report",
    "property_address": "216 E. Birch St. | Labarge | WY | 83123",
    "client_name": "James DeLaigle",
    "inspection_date": "2026-06-29",
    "status": "published",
    "share_token": "5b1bf9a2b56782f64d9027a6",
    "created_at": "2026-06-29T20:53:55.02772+00:00",
    "summary_text": "Overall, the home is in poor condition. The roof shows damage and past water intrusion at the penetrations and hip details. There are leaks in the plumbing system and there is significant water damage underneath the bathtub. The foundation for the home has settled and the floor is noticeably sloped. It does not appear a footing was poured for the foundation, and the stem wall is resting on the ground. The addition to the home has settled relative to the original foundation. The electrical in the home is outdated as well. No GFCI protection is provided in the home. The windows and doors in the home are old and do not operate smoothly. One of the windows is broken. Many of the windows are difficult to operate and move significantly in their frames. \n\nThe entire report must be read for a full list of observed defects. ",
    "home_photo_url": "https://lxlnbgjlxnwpfioiqaek.supabase.co/storage/v1/object/public/inspection-photos/d499cc39-424f-44ac-90b7-3c3f919ceb48/home/3bbdd87e-e503-4585-8019-857f1895e332.JPG",
    "inspector_name": "Douglas Macdonald",
    "gis_map_url": "https://lxlnbgjlxnwpfioiqaek.supabase.co/storage/v1/object/public/inspection-photos/d499cc39-424f-44ac-90b7-3c3f919ceb48/gis-map/f24ab732-7525-4ea4-a3ee-d1d8d5c39dd3.png"
  },
  {
    "id": "af85e2bf-6b8c-4215-8d7f-d6e165c8c02e",
    "title": "4 Beaver Ridge Rd. Home Inspection Report",
    "property_address": "4 Beaver Ridge Rd. | Daniel | 83115",
    "client_name": "Sean Jennings",
    "inspection_date": "2026-07-06",
    "status": "published",
    "share_token": "b5954540e9434b0cea325392",
    "created_at": "2026-07-06T23:54:54.389562+00:00",
    "summary_text": "Overall, the home is in good condition. The foundation and roof both appear to be performing well. There is some roof damage on the home, which is typical for homes in this area due to the extreme winter months. The standby generator for the home did not have enough charge in the battery to be operated. The generator should be tested after a new battery is installed. The home does not have proper firewall separation between the attached garage and the home. The wall between the home and the ceiling below the habitable space both require firewall separation. This can delay or prevent lending on some mortgage types. There are a few appliances in the home that are no longer operational or in use. The outdoor solid fuel furnace is no longer in use. The gas fireplace upstairs does not appear to be operational. The oven/range has a burner and oven element out. The entire report should be read for a full list of observed defects. ",
    "home_photo_url": "https://lxlnbgjlxnwpfioiqaek.supabase.co/storage/v1/object/public/inspection-photos/af85e2bf-6b8c-4215-8d7f-d6e165c8c02e/home/5e4b7c89-d43e-4980-81a1-edfae16a58db.JPG",
    "inspector_name": "Douglas Macdonald",
    "gis_map_url": "https://lxlnbgjlxnwpfioiqaek.supabase.co/storage/v1/object/public/inspection-photos/af85e2bf-6b8c-4215-8d7f-d6e165c8c02e/gis-map/8d4abc41-1635-458a-b41e-82db40a51b4d.png"
  },
  {
    "id": "4e38d458-65a1-4d92-ad2e-19837f089f2f",
    "title": "642 N. Maybell Home Inspection Report",
    "property_address": "642 N. Maybell | Pinedale | 82941",
    "client_name": "Kathleen Harrington",
    "inspection_date": "2026-07-13",
    "status": "published",
    "share_token": "9b211e95e338090afd1bc5b5",
    "created_at": "2026-07-13T22:41:28.678669+00:00",
    "summary_text": "Overall, the home is in fair condition. It is an older home that does have some typical signs of ageing. The roof covering may be original to the home. If so, the roof will likely need to be replaced soon. The foundation shows signs of settlement, especially around the master bedroom. The floor is noticeably sloped in this room. The SW corner appears to have dropped relative to the rest of the home. The crawlspace is not properly ventilated, and this may be causing moisture and mold problems in the space. It appears the sink drain has leaked in the past. If the leak has been fixed, water damaged insulation and vapor barrier should be removed. The masonry chimney is not properly supported in the crawlspace. This chimney and fireplace require their own footing and bracing in the crawlspace. \n\nThe entire report must be read for a full list of observed defects.  ",
    "home_photo_url": "https://lxlnbgjlxnwpfioiqaek.supabase.co/storage/v1/object/public/inspection-photos/4e38d458-65a1-4d92-ad2e-19837f089f2f/home/cabec309-a735-4d93-a6f5-ec8d55416fae.JPG",
    "inspector_name": "Douglas Macdonald",
    "gis_map_url": "https://lxlnbgjlxnwpfioiqaek.supabase.co/storage/v1/object/public/inspection-photos/4e38d458-65a1-4d92-ad2e-19837f089f2f/gis-map/56fb708e-094c-4269-ba2f-5ff481f16828.png"
  },
  {
    "id": "cc1b03ce-25ea-480c-a5c4-20741951c081",
    "title": "16 Maxwell Avenue Home Inspection Report",
    "property_address": "16 Maxwell Ave. | Big Piney | WY | 83113",
    "client_name": "Xavia Romero",
    "inspection_date": "2026-06-07",
    "status": "published",
    "share_token": "7092b99835e8e2334438fc86",
    "created_at": "2026-06-07T19:56:51.458167+00:00",
    "summary_text": "Overall, the home is in fair condition. The roof covering is worn on the South side, and may need to be replaced soon. Significant granule loss was observed on the composition shingle roof cover in this area. Exposed fiberglass mesh was observed on these shingles. This can lead to accelerated deterioration and may reduce the weather barrier provided by the shingle. Two rafter members were also observed to be significantly damaged. These members have split, and are no longer structurally sound. These rafters should be evaluated and corrected by a qualified roofer/structural engineer. The home's roof framing uses a prefabricated  truss design. Any repairs to the rafter system should be in accordance with the load plan for the truss system. \n\nThe water heater is not installed per the manufacturer's instructions. The metal flue pipe is contacting combustible materials. The water heater is installed in a confined space, and requires proper make-up air to ensure safe operation. There is also evidence of corrosion inside the furnace. This appears to be from the condensate collection system. The pipe connections inside the furnace cabinet appear to be leaking slightly. This should be evaluated and repaired by a qualified HVAC technician. ",
    "home_photo_url": "https://lxlnbgjlxnwpfioiqaek.supabase.co/storage/v1/object/public/inspection-photos/cc1b03ce-25ea-480c-a5c4-20741951c081/home/2bf8ca78-1156-4f1c-b527-362574708218.JPG",
    "inspector_name": "Douglas Macdonald",
    "gis_map_url": "https://lxlnbgjlxnwpfioiqaek.supabase.co/storage/v1/object/public/inspection-photos/cc1b03ce-25ea-480c-a5c4-20741951c081/gis-map/5aa28c19-c5e9-4e1d-be6a-5814a5bbc50a.png"
  },
  {
    "id": "8e06ae14-5941-430a-b46b-657ec28d417e",
    "title": "457 S Lincoln Ave. Home Inspection Report",
    "property_address": "457 S Lincoln Ave. | Pinedale | WY | 82941",
    "client_name": "Darren Dueitt",
    "inspection_date": "2026-06-19",
    "status": "published",
    "share_token": "c7202bb435637440ee687a67",
    "created_at": "2026-06-19T21:31:26.026946+00:00",
    "summary_text": "Overall, the home is in good condition. The shingle roof is likely approaching the end of its economic life. There is exposed fiberglass on many of the shingles on the West side. There are several areas where the roof fasteners have pushed out of the sheathing. This is likely a result of elevated humidity in the attic space. This may be causing the sheathing to swell and force the nails out. Improving the ventilation in the attic would likely help this issue. The log siding is missing an appropriate seal between logs. Exposed insulation is visible in these gaps. The floor bracing system in the crawlspace has rotated. Additional bracing of the floor system is recommended to support the central load bearing wall and the wood stove platform. \n\nThe entire report must be read for a full discussion of observed defects. ",
    "home_photo_url": "https://lxlnbgjlxnwpfioiqaek.supabase.co/storage/v1/object/public/inspection-photos/8e06ae14-5941-430a-b46b-657ec28d417e/home/9547a821-4713-46e5-a0ef-cfa6a80fdbd7.jpg",
    "inspector_name": "Douglas Macdonald",
    "gis_map_url": "https://lxlnbgjlxnwpfioiqaek.supabase.co/storage/v1/object/public/inspection-photos/8e06ae14-5941-430a-b46b-657ec28d417e/gis-map/e0c7814f-4f59-4271-9211-6d5dc4b0bae1.png"
  },
  {
    "id": "4eea0e69-946b-4354-9629-fe1cbf64ad26",
    "title": "78 S. Fork Trail Home Inspection Report",
    "property_address": "78 S. Fork Trl. | Boulder | WY | 82923",
    "client_name": "Alec Charters",
    "inspection_date": "2026-06-14",
    "status": "published",
    "share_token": "756962053b56102cf2c412a5",
    "created_at": "2026-06-15T00:31:52.094685+00:00",
    "summary_text": "Overall, the home is in good condition. The roof and foundation appear to be performing well. There are a few electrical issues that should be addressed for safety. The current owners plan to bury a propane tank for the home as well. Currently, the only propane is used for the gas fireplace in the home. ",
    "home_photo_url": "https://lxlnbgjlxnwpfioiqaek.supabase.co/storage/v1/object/public/inspection-photos/4eea0e69-946b-4354-9629-fe1cbf64ad26/home/0eeed1d4-6359-4683-a99c-99b6e74a1a87.JPG",
    "inspector_name": "Douglas Macdonald",
    "gis_map_url": "https://lxlnbgjlxnwpfioiqaek.supabase.co/storage/v1/object/public/inspection-photos/4eea0e69-946b-4354-9629-fe1cbf64ad26/gis-map/666622c0-870e-443f-92a7-52d8d1fe0a09.png"
  },
  {
    "id": "76d56bd2-000e-423f-b84b-001ee66e9985",
    "title": "41 Redstone New Fork River Rd. Home Inspection Report",
    "property_address": "41 Redstone New Fork River Rd. | Pinedale | WY | 82941",
    "client_name": "Levi Lozier",
    "inspection_date": "2026-07-08",
    "status": "published",
    "share_token": "16092bf8b717825ef9cccc59",
    "created_at": "2026-07-08T21:06:10.414372+00:00",
    "summary_text": "Overall, the home is in good condition. The roof was replaced recently and only has some minor details that were not done correctly. The foundation appears to be performing well. The septic tank appears to have been pumped recently. The siding on the home has also been re-stained recently. The water pressure for the home is low. It is likely that the well is providing less than 10 gpm. The pressure at the tank is reading 20 PSI. This is much lower than the recommended 40 PSI minimum for residential homes. The water appears hard and does seem to have high concentrations of iron. There is also a noticeable sulfur smell to the water. The water heater is not installed per the manufacturer's guidelines. The sink in the laundry room is leaking as well. The kitchen sink appears to have leaked at some point in the past. There is water damage around this drain in the crawlspace. The home's windows have several broken seals. The space between the double panes has become fogged in several of the windows. The homeowner has attempted to remedy some of this fogging. \n\nThe entire report must be read for a full list of observed defects. ",
    "home_photo_url": "https://lxlnbgjlxnwpfioiqaek.supabase.co/storage/v1/object/public/inspection-photos/76d56bd2-000e-423f-b84b-001ee66e9985/home/19a0064c-c802-4583-8bf4-b87e6c8d2a63.png",
    "inspector_name": "Douglas Macdonald",
    "gis_map_url": "https://lxlnbgjlxnwpfioiqaek.supabase.co/storage/v1/object/public/inspection-photos/76d56bd2-000e-423f-b84b-001ee66e9985/gis-map/2019be42-cb71-488f-81ab-89cbe71e1d7c.png"
  }
]